FEI XIANG Medicine & Health Products Factory
|
|
| |
|
|
|
|

|

|
Click to enlarge image
|
Model Number |
SD-9000C |
SD9000?C Multi-Parameter Patient Monior
ECG
Hart rate range Adult 0~300bpm
Pediatric/Neonatal 5~250bpm
Bandwidth 0.05 Hz ~100Hz
Accuracy +-1%
Alarm range High/Low limits setting useradjustable auto memory
ECG lead GDN、I、II、III; avR、aVL 、avF、V1-V6
Resolution 1bpm
S-T segment analysis -2.0~2.0mv
Arrhythmia analysis Yes
Lead off alarm Yes audible and visible alarm
Sweep speed 12.5、 25 、 50mm/sec
Gain selection *1/2 、 *1 、 *2 、auto
Protection Withstand 4000vac/50hz voltage in isolation and work against eletrosurgical interfence and defibrillation
ECG lead/cable General lead/cable for adult Pediatric Neonatal patients
PULSE OXIMETRY(SPO2)
Display Spo2 value,pulse histogram,waveform,pulse
Range 0~100% for adult ,pediatric and neonatal patients
Resolution +-1%
Accuracy +-1%(70~100%)
+-2%(50~69%)
Pulse Range 0~300bpm
Pulse Accuracy +-2bpm
Probe Standard Adult finger clip
Optional Pediatric Y?type clip and neonatal wrap
Alarm High/low limlts setting useradjustable auto memory
NIBP
Method Autormatic oscillation
Parameters Systolic,diastolic,mean,pulse
Alarm High/low limlts setting useradjustable auto memory
Working mode Manual/Aautormatic/stat(5minutes)
Unit Mmhg/kpa selectable
MeasurEmentRange Adult 10~250mmhg
Pediatric 10~200 mmhg
Neonatal 10~135 mmhg
Cuff pressure range 0~320 mmhg
Cuff type Standard Adult
Optional Pediatric/Neonatal
Cuff inflation <10sec
Cuff deflation <20sec
CAPNOGRAGH(CO2) (optional)
Method Side-stream or main-stream
Display EtCO2,insCO2and RESP rate
Accuracy +-2mmhg
Range 0~99mmhg
Barometric range 500~800mmhg
IBP(dual channel optional) (optional)
Method Pressure transducer
Parameters Systolic,diastolic,mean artery Pressure
Accuracy +-2%
Positions ART,PA,CVP,RAP,LAP,ICP
ART 0~250mmhg
Range PA 0~120 mmhg
CVP -10~40 mmhg
TEMPERATURE(TEMP)
Measurement range 20~45oC
Resolution 0.1 oC
Accuracy +-0.1 oC
Probe Standard Skin surface
Optional Rectal/esophageal
Alarm High/low limlts setting useradjustable auto memory
PRINTER (optional)
Type Bulit-in thermal matrix recorder or external printer (optional)
Print Mode Real-time or event trigged recording or waveforms and texts
Power Supply 100~250VAC/47~63hz
Power Consumption About 50W
Gross weight 15kgs
Dimensions 276H*356W*168D
Battery Sealed lead acid rechargeable
Safety standard IEC601-1 (GB9706.1)
RESPIRATION(RESP)
Measurement Method Thoracic impedance
Respiration rate range 0~120bpm
Accuracy +-2%
Alarm High/low limlts setting useradjustable auto memory
DISPLAY
12.1?color TFT display
1. 12.1?color TFT display
2. S-T segment analysis
3. ECG wave freezing for manual analysis
4. Trend data analysis for 12//24/96 hours
5. 400-set paramenters store
6. Againest electrosurgical interference and defibrillation
7. Pacemarker detection
8. Suitable for adult ,pediatric and neonatal patients
9. Built-in rechargeable battery
10. Networking capability
|
|
|
|
| |
|
|
|